8 temperature sensor module MET148-2 for Sepam series 20, 40, 60, 80
请求报价
产品概览
| 库存情况 | 需按需确认 |
| 分类 | Easergy Sepam series 60 |
| 生命周期状态 | active |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
| 重量 | 0.2 kg |
发货与库存
59641 何时可以发货?
59641 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 59641 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 59641 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 59641 安排当日快递或专车加急配送。
External 8 temperature sensors module MET148-2 for Schneider Electric's protection relays. This module can be used to ensure direct temperature measurements with Resistance Temperature Detectors (RTDs). It can be connected to the protection relay any time: during installation, commissioning or even during maintenance. This module provides 8 Resistance Temperature Detector (RTD) inputs. External modules allow late versionizing for Partners and assure expandability of PowerLogic P5 features for End Users. This external module can work with Pt100, Ni100 and Ni120 types of Resistance Temperature Detectors. Connection is made thru screw-type terminals. This module does not require auxiliary power supply. It is powered by PowerLogic P5. The product dimensions are 88 mm in height (3.46 in), 144 mm in width (5.70 in) and 30 mm in depth 1.18 in) for a net weight of 200 g (0.440 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be installed on symmetrical DIN rail. Connection cords (59660, 59661, 59662). Connection cords (59660, 59661, 59662).
技术规格
Specifications
| Module type | Temperature sensor |
| Range of product | Sepam series 80, Sepam series 60, Sepam series 80 NPP, Sepam series 40, Sepam series 20 |
| Device short name | MET148-2 |
| Type of measurement | Temperature |
| Number of inputs | 8 |
| Temperature probe type | Ni 100/Ni 120, <4 mA isolation from earth: none, Pt 100, <4 mA isolation from earth: none |
| Mounting mode | Fixed |
| Mounting support | Symmetrical DIN rail |
| Height | 88 mm |
| Width | 144 mm |
| Depth | 30 mm |
| Net weight | 0.2 kg |
| Mechanical robustness | Earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3, Earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3, Jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2, Shocks de-energized (level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2, Shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2, Vibrations de-energized (level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1, Vibrations in operation (level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1, Vibrations in operation (level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6 |
| Auxiliary connection terminal | Earthing terminal: screw-type connectorscable <1000 m, Earthing terminal: screw-type connectorstinned copper braid 6…100 mm² <1000 m, RTDs: screw-type connectors1 cable(s) wire 0.2…2.5 mm², RTDs: screw-type connectors2 cable(s) wire 0.2…1 mm² |
| Maximum distance between sensor and module | 1 km |
| Tightening torque | Earthing terminal: 2.2 N.m |
| Electromagnetic compatibility | 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV DM, conforming to IEC 60255-22-1, 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 2.5 kV DM, conforming to ANSI C37.90.1, 100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV DM, conforming to IEC 61000-4-12, Conducted disturbance emission: (emission tests), conforming to IEC 60255-25, Conducted disturbance emission: (emission tests), A, conforming to EN 55022, Disturbing field emission: (emission tests), conforming to IEC 60255-25, Disturbing field emission: (emission tests), A, conforming to EN 55022, Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3, Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2, Fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1, Fast transient bursts: (immunity tests-conducted disturbances), A and B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4, Fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4, Immunity to conducted RF disturbances: (immunity tests-conducted disturbances), III, 10 V, conforming to IEC 60255-22-6, Immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (1-3 s), conforming to IEC 61000-4-8, Immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz...1 GHz, conforming to IEC 60255-22-3, Immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz...1 GHz, conforming to ANSI C37.90.2, Immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz...2 GHz, conforming to IEC 61000-4-3, Surges: (immunity tests-conducted disturbances), III, 2 kV CM, 1 kV DM, conforming to IEC 61000-4-5, Voltage interruptions: (immunity tests-conducted disturbances), 100 % during 100 ms, conforming to IEC 60255-11 |
| Climatic withstand | Influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60, Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60, Continuous exposure to damp heat (in operation) : Cab: 10 days, 93 % RH, 40 °C conforming to IEC 60068-2-78, Continuous exposure to damp heat (in storage) : Cab: 56 days, 93 % RH, 40 °C conforming to IEC 60068-2-78, Continuous exposure to damp heat (in storage) : Db: 6 days, 95 % RH, 55 °C conforming to IEC 60068-2-30, Exposure to cold (in operation) : Ad: - 25 °C conforming to IEC 60068-2-1, Exposure to cold (in storage) : Ab: - 25 °C conforming to IEC 60068-2-1, Exposure to dry heat (in operation) : Bd: 70 °C conforming to IEC 60068-2-2, Exposure to dry heat (in storage) : Bb: 70 °C conforming to IEC 60068-2-2, Salt mist (in operation) : Kb/2: 6 days conforming to IEC 60068-2-52, Temperature variation with specified variation rate (in storage) : Nb: - 25 °C to 70 °C, 5 °C/min conforming to IEC 60068-2-14 |
| Ambient air temperature for operation | -25…70 °C |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.100 cm |
| Package 1 Width | 12.300 cm |
| Package 1 Length | 18.300 cm |
| Package 1 Weight | 232.600 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 8 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 2.161 kg |
| Warranty (in months) | 18 |