产品概览
| 库存情况 | 需按需确认 |
| 分类 | Analogue infrared temperature sensors with display |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
TW2011 何时可以发货?
TW2011 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 TW2011 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 TW2011 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 TW2011 安排当日快递或专车加急配送。
Reliable, non-contact temperature measurement of objects with very high temperatures For applications in the steel and glass industries Intuitive setting of analogue output and switching output via pushbutton Clearly visible display for showing the current temperature Robust housing and scratch-resistant precision lens for use in harsh industrial environments Convenient operation via buttons or parameter setting via IO-Link
技术规格
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range | 300...1600 °C; 572...2912 °F |
| 300...1600 °C | 572...2912 °F |
| Communication interface | IO-Link |
Application
| Application | tempering temperatures; glass melting; graphite; ceramics; metals; forging; sintering; heat treatment; rolling |
Electrical data
| Operating voltage[V] [V] | 18...32 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | < 50 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (50 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 1 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Inputs
| Test input | type 3 (IEC 61131-2) |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 150 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | 500 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Short-circuit proof | yes |
| Overload protection | yes |
Detection zone
| Wave length range[µm] [µm] | 1...1.7 |
Measuring/setting range
| Measuring range | 300...1600 °C; 572...2912 °F |
| 300...1600 °C | 572...2912 °F |
| Set point SP | 301...1600 °C; 574...2912 °F |
| 301...1600 °C | 574...2912 °F |
| Reset point rP | 300...1599 °C; 572...2910 °F |
| 300...1599 °C | 572...2910 °F |
| Analogue start point | 300...1400 °C; 572...2552 °F |
| 300...1400 °C | 572...2552 °F |
| Analogue end point | 500...1600 °C; 932...2912 °F |
| 500...1600 °C | 932...2912 °F |
| In steps of | 1 °C; 1 °F |
| 1 °C | 1 °F |
| Resolution of switching output[K] [K] | 1 |
| Resolution of analogue output[K] [K] | 0.2; (+ 0.03% of the set measuring span) |
| Resolution of display[K] [K] | 1 |
Accuracy / deviations
| Accuracy[K] [K] | < ± 0,5 %; (of measured value, min. 4 K (degree of emission = 1, T = 23 °C)) |
| Repeatability[K] [K] | 1 |
Response times
| Response time[ms] [ms] | 2; (T > 600 °C) |
Software / programming
| Adjustment of the switch point | programming buttons |
| Parameter setting options | analogue range; normally open / normally closed; switch-on/switch-off delay; Damping; Peakhold; emissivity; simulation function |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable; Function; Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 16 |
| Process data binary | 1 |
| Min. process cycle time[ms] [ms] | 3.6 |
| Supported DeviceIDs | default; 719 |
| default | 719 |
Operating conditions
| Ambient temperature[°C] [°C] | 0...65 |
| Note on ambient temperature | fibre optics and measuring head: -20...250 °C |
| Storage temperature[°C] [°C] | -20...80 |
| Max. relative air humidity[%] [%] | 95; (non condensing) |
| Protection | IP 65 |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-4 |
| Shock resistance | DIN EN 60068-2-27; 30 g (11 ms) |
| DIN EN 60068-2-27 | 30 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 5 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 74 |
Mechanical data
| Weight[g] [g] | 899.5 |
| Housing | threaded type |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 188 |
| Thread designation | M30 x 1.5 |
| Fibre optic connection | ¼"-36UNS-2A |
| Materials | threaded sleeve: stainless steel (303/1.4305); polyester |
| Lens material | tempered optical glass |
Displays / operating elements
| 3 | pushbuttons |
| Display | Display unit; 2 x LED, yellow; switching status; 1 x LED, yellow; function display; 7-segment LED display, 4-digit; measured values; 7-segment LED display, 4-digit |
| Display unit | 2 x LED, yellow |
| switching status | 1 x LED, yellow |
| function display | 7-segment LED display, 4-digit |
| measured values | 7-segment LED display, 4-digit |
| Operating elements | 3; pushbuttons |
Accessories
| Items supplied | lock nuts: 2; fibre optic: 2 m; Measuring head |
Remarks
| Remarks | Use a screened cable to protect infrared temperature sensors from interference.; The screen must be connected to the housing of the sensor via the connector.; On delivery the sensor is premounted and calibrated and is supplied with 2 m fibre optic.; If the fibre optic is replaced the sensor has to be recalibrated (ZC0062). |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12 |
12个月保修适用于所有全新库存
3个月保修适用于二手及翻新零部件
30天退货未使用零部件退货免收上架费
全球发货全球快速可追踪配送