产品概览
| 库存情况 | 需按需确认 |
| 分类 | Self-monitoring transmitters for the food industry |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
TCC291 何时可以发货?
TCC291 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 TCC291 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 TCC291 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 TCC291 安排当日快递或专车加急配送。
Immediate notification of deviations in accuracy Improved quality assurance in between calibration intervals Robust design for permanently precise measurements even in demanding environments Transparent sensor monitoring thanks to logging of the diagnostic values Simulation function simplifies installation Precise analogue output and user-friendly communication via IO-Link
技术规格
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range | -25...160 °C; -13...320 °F |
| -25...160 °C | -13...320 °F |
| Communication interface | IO-Link |
| Process connection | clamp adapter Ø 6 mm |
| Installation length EL[mm] [mm] | 350 |
Application
| Special feature | Gold-plated contacts |
| Measuring element | 1 x Pt 1000 |
| Reference element | 1 x NTC |
| Media | liquids and gases |
| Pressure rating | 160 bar; 16 MPa |
| 160 bar | 16 MPa |
| Minimum installation depth[mm] [mm] | 15 |
Electrical data
| Operating voltage[V] [V] | 18...32 DC; ("supply class 2" to cULus) |
| Current consumption[mA] [mA] | 10; (24 V) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 6 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | analogue signal; IO-Link; (calibration check status) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 1 |
| Output function | normally closed; (diagnostic signal) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Diagnostic output | calibration check status and error diagnostics |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20 |
| Max. load[Ω] [Ω] | (Ub - 15 V) x 50 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Probe length L[mm] [mm] | 350 |
| Measuring range | -25...160 °C; -13...320 °F |
| -25...160 °C | -13...320 °F |
| Note on measuring range | scalable |
| Factory setting | -10...150 °C / 14...302 °F |
| Calibration check limit[K] [K] | 0.5...3 |
| In steps of[K] [K] | 0.05 |
| Resolution of analogue output[K] [K] | 0.05 |
Accuracy / deviations
| Precision analogue output[K] [K] | ± 0,2 |
| Precision IO-Link[K] [K] | ± 0,2 |
| Temperature coefficient analogue output[% of the span / 10 K] [% of the span / 10 K] | < ± 0,02; (in case of deviation from the reference condition 25 ± 5 °C) |
| Temperature coefficient IO-Link[% of the span / 10 K] [% of the span / 10 K] | < ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C) |
Response times
| Dynamic response T05 / T09[s] [s] | 1,5 / 4 |
Software / programming
| Parameter setting options | Display unit; scaling of the analogue output; calibration check limit; switching logic diagnostic output; simulation mode |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | BLOB; Binary Large Object transfer; Common - I&D; Identification and Diagnosis; Function; Measurement data, standard resolution |
| BLOB | Binary Large Object transfer |
| Common - I&D | Identification and Diagnosis |
| Function | Measurement data, standard resolution |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 1 |
| Process data binary | 1 |
| Min. process cycle time[ms] [ms] | 4.4 |
| IO-Link resolution temperature[K] [K] | 0.01 |
| Supported DeviceIDs | default; 1129 |
| default | 1129 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...70 |
| Note on ambient temperature | max. internal device temperature: 125 °C |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 68; IP 69K |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 68000-2-27; 50 g (11 ms) |
| DIN EN 68000-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 35 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 35 g (10...2000 Hz) |
| MTTF[years] [years] | 329 |
| Note on approval | factory certificate available as download at www.factory-certificate.ifm |
| UL approval | UL approval no.; K021; File number UL; E217884 |
| UL approval no. | K021 |
| File number UL | E217884 |
Mechanical data
| Weight[g] [g] | 315.6 |
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 50 / L = 393.5 |
| Materials | stainless steel (316L/1.4404); PEI; FKM; PFA |
| Materials (wetted parts) | stainless steel (316L/1.4404) |
| Process connection | clamp adapter Ø 6 mm |
| Surface characteristics Ra/Rz of the wetted parts | Ra < 0.8 µm |
| Probe diameter[mm] [mm] | 6 |
| Installation length EL[mm] [mm] | 350 |
Remarks
| Remarks | MS = set measuring span; operating voltage "supply class 2" according to cULus |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |
12个月保修适用于所有全新库存
3个月保修适用于二手及翻新零部件
30天退货未使用零部件退货免收上架费
全球发货全球快速可追踪配送