Reliable detection of flow and medium temperature With switching output or frequency output and IO-Link Display can be rotated for optimum alignment Clearly readable colour display with red/green colour change Suitable for water, deionised water and cooling water Convenient operation via buttons or parameter setting via IO-Link
技术规格
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2 |
| Measuring range | 1...20 l/min; 0.06...1.2 m³/h |
| 1...20 l/min | 0.06...1.2 m³/h |
| Process connection | threaded connection G 1/2 internal thread DN8 |
Application
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Media | water; glycol solutions; coolants |
| Medium temperature[°C] [°C] | -10...90 |
| Pressure rating | 12 bar; 1.2 MPa |
| 12 bar | 1.2 MPa |
| Note on pressure rating | up to 40 °C |
| MAWP for applications according to CRN[bar] [bar] | 3.9 |
Electrical data
| Operating voltage[V] [V] | 18...30 DC |
| Current consumption[mA] [mA] | < 30 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 3 |
| Measuring principle | Vortex |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; frequency signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Short-circuit protection | yes |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 1...20 l/min; 0.06...1.2 m³/h |
| 1...20 l/min | 0.06...1.2 m³/h |
| Display range | 0...24 l/min; 0...1.44 m³/h |
| 0...24 l/min | 0...1.44 m³/h |
| Resolution | 0.1 l/min; 0.005 m³/h |
| 0.1 l/min | 0.005 m³/h |
| Set point SP | 1.2...20 l/min; 0.07...1.2 m³/h |
| 1.2...20 l/min | 0.07...1.2 m³/h |
| Reset point rP | 1...19.8 l/min; 0.06...1.19 m³/h |
| 1...19.8 l/min | 0.06...1.19 m³/h |
| Frequency end point, FEP | 4...20 l/min; 0.24...1.2 m³/h |
| 4...20 l/min | 0.24...1.2 m³/h |
| In steps of | 0.1 l/min; 0.005 m³/h |
| Frequency at the end point FRP[Hz] [Hz] | 100...1000 |
| Measuring dynamics | 1:20 |
| Measuring range[°C] [°C] | -10...90 |
| Display range[°C] [°C] | -30...110 |
| Resolution[°C] [°C] | 0.5 |
| Set point SP[°C] [°C] | -9...90 |
| Reset point rP[°C] [°C] | -10...89 |
| In steps of[°C] [°C] | 0.5 |
| Frequency start point, FSP[°C] [°C] | -10...70 |
| Frequency end point, FEP[°C] [°C] | 10...90 |
Accuracy / deviations
| Accuracy (in the measuring range) | ± 2 % MEW; (water) |
| Repeatability | ± 0,5 % MEW |
| Accuracy[K] [K] | ± 1 |
Response times
| Response time[s] [s] | 1; (dAP = 0) |
| Damping process value dAP[s] [s] | 0...5 |
| Dynamic response T05 / T09[s] [s] | T09 = 6 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; frequency output; switch-on/switch-off delay; Damping; Display unit |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable; Function; Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 2 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 3 |
| Supported DeviceIDs | default; 484 |
| default | 484 |
Operating conditions
| Ambient temperature[°C] [°C] | 0...60 |
| Note on ambient temperature | medium temperature < 80 °C; medium temperature < 90 °C: 0...50 °C |
| Storage temperature[°C] [°C] | -20...80 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-3 |
| CPA approval | model number; 001VO; accuracy class; -; maximum allowable error; ± 2 % FS; Q (min); 0,09 m³/h; Q (t); 0,24 m³/h; Q (max); 1,2 m³/h |
| model number | 001VO |
| accuracy class | - |
| maximum allowable error | ± 2 % FS |
| Q (min) | 0,09 m³/h |
| Q (t) | 0,24 m³/h |
| Q (max) | 1,2 m³/h |
| Shock resistance | DIN EN 60068-2-27; 5 g (11 ms) |
| DIN EN 60068-2-27 | 5 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; with water / 10...50 Hz 1 mm; with water / 50...2000 Hz 2 g |
| DIN EN 60068-2-6 | with water / 10...50 Hz 1 mm |
| MTTF[years] [years] | 342 |
| UL approval | UL approval no.; I001 |
| UL approval no. | I001 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 474 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 110 x 45 x 72 |
| Materials | stainless steel (316L/1.4404); PC; PBT+PC-GF30; PPS; TPE-U |
| Materials (wetted parts) | stainless steel (316L/1.4404); ETFE; PA 6T; PPS; FKM |
| Tightening torque[Nm] [Nm] | 30 |
| Process connection | threaded connection G 1/2 internal thread DN8 |
Displays / operating elements
| Display | colour display 1,44", 128 x 128 pixels; 2 x LED, yellow |
Remarks
| Remarks | MW = measured value; MEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |