可按需提供

IFM SMF420

制造商料号: SMF420 · 品牌: IFM
价格面议
请求报价

工作人员将亲自回复,通常在1个工作日内——详见我们的 隐私政策.

12个月保修(全新)· 3个月(二手/翻新)
30天退货,未使用零部件退货免收上架费
发货方式

产品概览

库存情况需按需确认
分类Magnetic-inductive volumetric flow meters
保修12个月(全新)· 3个月(二手/翻新)

发货与库存

SMF420 何时可以发货?

SMF420 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。

可以亲自到店提取 SMF420 吗?

可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。

是否提供快递服务?

可以——在为 SMF420 申请报价时告诉我们,我们会在回复中附上快递发货选项。

我们的工厂停产了,急需这个零部件——你们能帮忙吗?

如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 SMF420 安排当日快递或专车加急配送。

Magnetic-inductive flow meter (SM Foodmag series) for the food and beverage industry Measured variables: flow rate, total volume, temperature, conductivity and fluid detection Easy to set up thanks to app-based menu, guided installation and hygienic pushbuttons Reduced cabling by combining supply voltage and output signals via an M12 connection Housing design increases shock and vibration resistance Convenient operation via buttons or parameter setting via IO-Link

技术规格

Product characteristics

Measuring range10...1200 l/min; 600...72000 l/h; 0.09...10 m/s; 0.6...72 m³/h
10...1200 l/min600...72000 l/h
Nominal diameterDN50 (2“)
Process connectionifm-specific device flange

Application

Special featureGold-plated contacts
Applicationfood and beverage industry
Mediaconductive liquids; water; hydrous media
Note on mediafood products such as beer, milk, fruit juices, soft drinks, ketchup, yoghurt, yoghurt toppings, ice cream; conductivity: ≥ 5 µS/cm
Medium temperature[°C] [°C]-20...150
Min. burst pressure37.5 bar; 3.75 MPa
37.5 bar3.75 MPa
Pressure rating25 bar; 2.5 MPa
25 bar2.5 MPa

Electrical data

Operating voltage[V] [V]18...32 DC
Current consumption[mA] [mA]250; (24V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]< 5
Measuring principlemagnetic-inductive

Inputs / outputs

Total number of inputs and outputs2

Inputs

InputsOUT2; external totaliser reset
OUT2external totaliser reset

Outputs

Total number of outputs2
Output signalOUT1; pulse signal; totaliser switching signal; diagnostic signal; IO-Link; OUT2; analogue signal; pulse signal; totaliser switching signal; diagnostic signal
OUT1pulse signal; totaliser switching signal; diagnostic signal; IO-Link
OUT2analogue signal; pulse signal; totaliser switching signal; diagnostic signal
Electrical designPNP/NPN
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (skalierbar)
Max. load[Ω] [Ω]500
Resolution of analogue output0.38 µA
Number of digital outputs2
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]100
Switching frequency DC[Hz] [Hz]0...10000

Measuring/setting range

Measuring range10...1200 l/min; 600...72000 l/h; 0.09...10 m/s; 0.6...72 m³/h
10...1200 l/min600...72000 l/h
Display range-1440...1440 l/min; -86400...86400 l/h; -12...12 m/s; -86.4...86.4 m³/h
-1440...1440 l/min-86400...86400 l/h
Resolution0.1 l/min; 50 l/h; 0.01 m/s; 0.05 m³/h
0.1 l/min50 l/h
Note on factory setting0...18,0 m³/h
Analogue start point ASP-1200...960 l/min; -72000...57600 l/h; -10.19...8.19 m/s; -72...57.6 m³/h
-1200...960 l/min-72000...57600 l/h
Analogue end point AEP-960...1200 l/min; 57600...72000 l/h; -8.19...10.19 m/s; -57.6...72 m³/h
-960...1200 l/min57600...72000 l/h
Low flow cut-off LFC0...960 l/min; 0...57600 l/h; 0...8.19 m/s; 0...57.6 m³/h
0...960 l/min0...57600 l/h
Pulse length[s] [s]0.00005...2
Pulse value0.002...99990000 I
Measuring range[°C] [°C]-20...150
Display range[°C] [°C]-20...150
Resolution[°C] [°C]0.01
Analogue start point[°C] [°C]-20...116
Analogue end point[°C] [°C]14...150
Measuring range[µS/cm] [µS/cm]100...100000
Display range[µS/cm] [µS/cm]0...10000000
Resolution[µS/cm] [µS/cm]1
Analogue start point[µS/cm] [µS/cm]0...80000
Analogue end point[µS/cm] [µS/cm]20000...100000

Accuracy / deviations

Accuracy (under reference conditions)with optional factory calibration (availability is being planned); ± (0,2 % MW + 2 mm/s); standard; ± (0,5 % MW + 1,5 mm/s)
with optional factory calibration (availability is being planned)± (0,2 % MW + 2 mm/s)
standard± (0,5 % MW + 1,5 mm/s)
Repeatability± 5% MW
Accuracy[K] [K]± 1
Repeatability[K] [K]± 0,5
Accuracy (in the measuring range)in the range of 100...20000 µS/cm; ±10% MW; in the range of 20000...100000 µS/cm; ±20% MW
in the range of 100...20000 µS/cm±10% MW
in the range of 20000...100000 µS/cm±20% MW

Response times

Response time[s] [s]< 2
Damping process value dAP[s] [s]0...5

Software / programming

Diagnostic functionsdirection of flow detection; liquid detection

Interfaces

Communication interfaceIO-Link
Transmission typeCOM3 (230,4 kBaud)
IO-Link revision1.1.3
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 4.3.4; Measuring and Switching Sensor, floating point, 4 channel; BLOB; Binary Large Object transfer; Common - I&D; Identification and Diagnosis; Extension; Sensor Control Wide; Extension; Quantity detection, switches when value exceeds the setpoint; Function; Locator; Function; ProductURI
Smart Sensor - SSP 4.3.4Measuring and Switching Sensor, floating point, 4 channel
BLOBBinary Large Object transfer
Common - I&DIdentification and Diagnosis
ExtensionQuantity detection, switches when value exceeds the setpoint
FunctionProductURI
SIO modeyes
Required master port typeA
Process data analogue6
Process data binary8
Min. process cycle time[ms] [ms]1.9
IO-Link process data (cyclical)totaliser; 32; flow; 32; temperature; 32; conductivity; 32; status; 4; binary switching information; 8
totaliser32
flow32
temperature32
conductivity32
status4
binary switching information8
IO-Link functions (acyclical)direction of flow detection; totaliser; memory; operating hours counter; internal temperature; simulation function
Supported DeviceIDsdefault; 1639
default1639

Operating conditions

Ambient temperature[°C] [°C]-20...65
Storage temperature[°C] [°C]-20...80
ProtectionIP 67; IP 69; (to DIN EN 60529)

Tests / approvals

EMCDIN 61326-1
CPA approvalmodel number; SMF; accuracy class; 0,5
model numberSMF
accuracy class0,5
Shock resistanceDIN IEC 68-2-27; 20 g (18ms)
DIN IEC 68-2-2720 g (18ms)
Vibration resistanceDIN IEC 68-2-6; 5 g (10...2000Hz)
DIN IEC 68-2-65 g (10...2000Hz)
MTTF[years] [years]81
UL approvalUL approval no.; I031
UL approval no.I031
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]5798.2
Housingcylindrical
Inlet pipe length5 x DN
Outlet pipe length2 x DN
Dimensions[mm] [mm]Ø 139.7 / L = 140
Materialshousing: stainless steel (316L/1.4404); flange: stainless steel (304/1.4301); electronics fixture: stainless steel (304/1.4301); electronics: stainless steel (316L/1.4404); Display: polysulfone; Display-Sealing: FKM; LED ring: PP
Materials (wetted parts)Pipe section: PFA; electrodes: stainless steel (316L/1.4435)
Nominal diameterDN50 (2“)
Process connectionifm-specific device flange
Surface characteristics Ra/Rz of the wetted partsRa < 0.4 μm

Displays / operating elements

4capacitive pushbuttons
Displayprocess value; full graphics TFT display, multi-colour 3,5" 320 x 240 Pixel; display layouts: 4; display rotation: 4 x 90°; operating status; LED ring, three-colour
process valuefull graphics TFT display, multi-colour 3,5" 320 x 240 Pixel
operating statusLED ring, three-colour
Display unitl/min; l/h; hl/min; hl/h; m³/min; m³/h; m/s; °C; μS/cm; S/m; ms/cm
Factory settingm³/h; °C; μS/cm
LanguageGerman; English; Spanish; French; Italian; Japanese; Korean; Portuguese; Chinese
Operating elements4; capacitive pushbuttons

Remarks

RemarksMW = measured value; MEW = Final value of the measuring range; pulse and totaliser signal are only available for one of the two outputs; reference conditions (1/2): water (free of gas bubbles), 15...35 °C, process connection: DIN32676 series A, pipe standard suitable for process connection; reference conditions (2/2): inlet pipe length 10xDN, outlet pipe length 5xDN, device settling time: 30 minutes, device orientation: horizontal, display orientation: up; accuracy specifications according to factory certificate on delivery
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated
12个月保修适用于所有全新库存
3个月保修适用于二手及翻新零部件
30天退货未使用零部件退货免收上架费
全球发货全球快速可追踪配送

更多 IFM 产品

IFM O8H205可按需提供IFM O8H205
制造商料号: O8H205 · IFM
价格面议
请求报价
IFM O8H206可按需提供IFM O8H206
制造商料号: O8H206 · IFM
价格面议
请求报价
IFM O8H207可按需提供IFM O8H207
制造商料号: O8H207 · IFM
价格面议
请求报价
IFM O8H202可按需提供IFM O8H202
制造商料号: O8H202 · IFM
价格面议
请求报价