产品概览
| 库存情况 | 需按需确认 |
| 分类 | Radar area sensors |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
R2D212 何时可以发货?
R2D212 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 R2D212 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 R2D212 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 R2D212 安排当日快递或专车加急配送。
Angular resolution for precise output of position coordinates Reliable measurements even in precipitation, fog, dust and dirt Individual adjustment of the horizontal and vertical detection range Operating modes can be set in accordance with the specific application Intuitive set-up and visualisation of the measured data using the ifm Vision Assistant software
技术规格
Product characteristics
| Communication interface | IO-Link |
| Housing | rectangular |
| Dimensions[mm] [mm] | 80 x 80 x 45 |
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (parameterisable) |
Application
| Radio approval for | Argentina; India |
Electrical data
| Operating voltage[V] [V] | 10...30 DC; (to SELV/PELV ; energy-limited circuits according to IEC/UL 61010-1 3rd ed. cl. 9.4) |
| Current consumption[mA] [mA] | < 300; (mean value: 150 mA) |
| Power consumption[W] [W] | 21; (maximum) |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time[ms] [ms] | 1000 |
| Operating frequency [GHz] | 76...77 |
| Mean radiated power | 24 |
Inputs / outputs
| Total number of inputs and outputs | 3 |
Inputs
| Inputs | IN1; activation/deactivation of the radar |
| IN1 | activation/deactivation of the radar |
Outputs
| Total number of outputs | 2 |
| Output signal | OUT1; switching signal; IO-Link; OUT2; switching signal |
| OUT1 | switching signal; IO-Link |
| OUT2 | switching signal |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 200 |
Detection zone
| Range[m] [m] | 0.35...50; (referred to E23013) |
| Angle of aperture cylindrical[°] [°] | horizontal; 140; vertical; 30 |
| horizontal | 140 |
| vertical | 30 |
| Note | static objects are not stably detected in the range < 1 m |
Measuring/setting range
| Measuring range[m] [m] | 0.35...50; (see diagram:) |
| Sampling rate[Hz] [Hz] | 20 |
| Note | static objects are not stably detected in the range < 1 m |
Software / programming
| Parameter setting options | only via IO-Link |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM3 (230,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | BLOB; Binary Large Object transfer; Common - I&D; Identification and Diagnosis; Function; Locator; Function; ProductURI |
| BLOB | Binary Large Object transfer |
| Common - I&D | Identification and Diagnosis |
| Function | ProductURI |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 3.2 |
| IO-Link process data (cyclical) | alarm zone status; 8; position X of object 1; 16; position Y of object 1; 16; speed X of object 1; 16; speed Y of object 1; 16; performance of object 1; 8; RCS of object 1; 8; confidence of object 1; 8; position X of object 2; 16; position Y of object 2; 16; speed X of object 2; 16; speed Y of object 2; 16; performance of object 2; 8; RCS of object 2; 8; confidence of object 2; 8; device status; 4; sensor inclination; 1 |
| alarm zone status | 8 |
| position X of object 1 | 16 |
| position Y of object 1 | 16 |
| speed X of object 1 | 16 |
| speed Y of object 1 | 16 |
| performance of object 1 | 8 |
| RCS of object 1 | 8 |
| confidence of object 1 | 8 |
| position X of object 2 | 16 |
| position Y of object 2 | 16 |
| speed X of object 2 | 16 |
| speed Y of object 2 | 16 |
| performance of object 2 | 8 |
| RCS of object 2 | 8 |
| confidence of object 2 | 8 |
| device status | 4 |
| sensor inclination | 1 |
| IO-Link functions (acyclical) | application specific tag; operating hours counter; number of trigger events; internal temperature; ROI setting; switch-on delays; transmitter can be switched off |
| Supported DeviceIDs | default; 1520 |
| default | 1520 |
| Note | For further information please see the IODD PDF file under "Downloads" |
Operating conditions
| Ambient temperature[°C] [°C] | -40...85 |
| Storage temperature[°C] [°C] | -40...85 |
| Protection | IP 65; IP 66; IP 67; IP 69K; (with mounted connectors or protective caps) |
Tests / approvals
| EMC | DIN EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; DIN EN 61000-4-3 HF radiated; 10 V/m; DIN EN 61000-4-4 Burst; 2 kV; DIN EN 61000-4-6 HF conducted; 10 V; DIN EN 61000-6-2; immunity / industrial environments; EN 55032 emission; Class A |
| DIN EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| DIN EN 61000-4-3 HF radiated | 10 V/m |
| DIN EN 61000-4-4 Burst | 2 kV |
| DIN EN 61000-4-6 HF conducted | 10 V |
| DIN EN 61000-6-2 | immunity / industrial environments |
| EN 55032 emission | Class A |
| Impact resistance | IEC 62262; IK06 (1J) |
| IEC 62262 | IK06 (1J) |
| Vibration resistance | DIN EN 60068-2-6 Fc; 10 g 10 frequency cycles, 1 octave/minute, in 3 axes |
| DIN EN 60068-2-6 Fc | 10 g 10 frequency cycles, 1 octave/minute, in 3 axes |
| Shock resistance | DIN EN 60068-2-27 Ea; 50 g 11 ms half-sine; 10 shocks each in every direction along the 3 coordinate axes |
| DIN EN 60068-2-27 Ea | 50 g 11 ms half-sine; 10 shocks each in every direction along the 3 coordinate axes |
| Continuous shock resistance | DIN EN 60068-2-29 Eb; 40 g 6 ms half-sine; 4,000 shocks each in every direction along the 3 coordinate axes |
| DIN EN 60068-2-29 Eb | 40 g 6 ms half-sine; 4,000 shocks each in every direction along the 3 coordinate axes |
| Fast temperature change | DIN EN 60068-2-14 Na; TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 30 s; 300 cycles |
| DIN EN 60068-2-14 Na | TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 30 s; 300 cycles |
| Salt spray test | DIN EN 60068-2-11 Ka; 8 test cycles |
| DIN EN 60068-2-11 Ka | 8 test cycles |
| Electrical safety | DIN EN 61010-2-201; electric shock / electrical supply only via SELV/PELV circuits |
| DIN EN 61010-2-201 | electric shock / electrical supply only via SELV/PELV circuits |
| MTTF[years] [years] | 54 |
Mechanical data
| Weight[g] [g] | 402.9 |
| Housing | rectangular |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | 80 x 80 x 45 |
| Materials | housing: PA; radome: PEI; Sealing: HNBR |
Displays / operating elements
| Display | switching status; 2x LED, yellow; operation; 1x LED, green; errors; 1x LED, red |
| switching status | 2x LED, yellow |
| operation | 1x LED, green |
| errors | 1x LED, red |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A |
12个月保修适用于所有全新库存
3个月保修适用于二手及翻新零部件
30天退货未使用零部件退货免收上架费
全球发货全球快速可追踪配送