For applications in hazardous areas Two switching outputs, one of which can be configured as diagnostic output Clearly visible 4-digit LED display Robust stainless steel housing for use in harsh industrial environments Lifespan of more than 100 million pressure cycles Convenient operation via buttons or parameter setting via IO-Link

技术规格

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2
Measuring range0...2.5 bar; 0...2500 mbar; 0...36.3 psi; 0...250 kPa
0...2.5 bar0...2500 mbar
Process connectionthreaded connection G 1/4 internal thread

Application

Special featureGold-plated contacts
Applicationfor industrial applications
Medialiquids and gases
Medium temperature[°C] [°C]-20...60
Min. burst pressure50 bar; 725 psi; 5000 kPa
50 bar725 psi
Pressure rating20 bar; 290 psi; 2000 kPa
20 bar290 psi
Type of pressurerelative pressure

Electrical data

Operating voltage[V] [V]18...36 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 50
Protection classIII
Reverse polarity protectionyes
Overvoltage protectionyes; (< 40 V)
Power-on delay time[s] [s]0.3
Integrated watchdogyes

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2

Outputs

Total number of outputs2
Output signalswitching signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250
Switching frequency DC[Hz] [Hz]< 170
Short-circuit protectionyes
Type of short-circuit protectionpulsed

Measuring/setting range

Measuring range0...2.5 bar; 0...2500 mbar; 0...36.3 psi; 0...250 kPa
0...2.5 bar0...2500 mbar
Set point SP0.02...2.5 bar; 0.4...36.2 psi; 2...250 kPa
0.02...2.5 bar0.4...36.2 psi
Reset point rP0.01...2.49 bar; 0.2...36 psi; 1...249 kPa
0.01...2.49 bar0.2...36 psi
In steps of0.01 bar; 0.2 psi; 1 kPa
0.01 bar0.2 psi
Factory settingSP1 = 0.63 bar; rP1 = 0.58 bar; SP2 = 1.88 bar; rP2 = 1.83 bar
SP1 = 0.63 barrP1 = 0.58 bar
SP2 = 1.88 barrP2 = 1.83 bar

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,5
Repeatability[% of the span] [% of the span]< ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span] [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span] [% of the span]< ± 0,25
Long-term stability[% of the span] [% of the span]< ± 0,05; (per 6 months)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]0,2; (0...60 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]0,2; (0...60 °C)

Response times

Delay time programmable dS, dr[s] [s]0; 0,2...50

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
SIO modeyes
Required master port typeA
Process data analogue1
Process data binary2
Min. process cycle time[ms] [ms]2.3
Supported DeviceIDsdefault; 312
default312

Operating conditions

Ambient temperature[°C] [°C]-20...60
Storage temperature[°C] [°C]-40...100
ProtectionIP 65

Tests / approvals

ATEX markingII 3D Ex tc IIIC T80°C Dc X
EMCEN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; 0,5/1 kV; EN 61000-4-6 HF conducted; 10 V
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated10 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-5 Surge0,5/1 kV
EN 61000-4-6 HF conducted10 V
Shock resistanceDIN IEC 68-2-27; 50 g (11 ms)
DIN IEC 68-2-2750 g (11 ms)
Vibration resistanceDIN IEC 68-2-6; 20 g (10...2000 Hz)
DIN IEC 68-2-620 g (10...2000 Hz)
MTTF[years] [years]194
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]303
Housingcylindrical
Dimensions[mm] [mm]Ø 36 / L = 94
Materialsstainless steel (304/1.4301); stainless steel (316L/1.4404); PC; PBT; PEI; FKM; PTFE
Materials (wetted parts)stainless steel (303/1.4305); ceramics; FKM
Min. pressure cycles100 million
Process connectionthreaded connection G 1/4 internal thread
Restrictor element integratedno (can be retrofitted)

Displays / operating elements

DisplayDisplay unit; 3 x LED, green; switching status; 2 x LED, yellow; function display; alphanumeric display, 4-digit; measured values; alphanumeric display, 4-digit
Display unit3 x LED, green
switching status2 x LED, yellow
function displayalphanumeric display, 4-digit
measured valuesalphanumeric display, 4-digit

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated
12个月保修适用于所有全新库存
3个月保修适用于二手及翻新零部件
30天退货未使用零部件退货免收上架费
全球发货全球快速可追踪配送

更多 IFM 产品

IFM O8H205可按需提供IFM O8H205
制造商料号: O8H205 · IFM
价格面议
请求报价
IFM O8H206可按需提供IFM O8H206
制造商料号: O8H206 · IFM
价格面议
请求报价
IFM O8H207可按需提供IFM O8H207
制造商料号: O8H207 · IFM
价格面议
请求报价
IFM O8H202可按需提供IFM O8H202
制造商料号: O8H202 · IFM
价格面议
请求报价