产品概览
| 库存情况 | 需按需确认 |
| 分类 | All pressure sensors / vacuum sensors |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
PG1743 何时可以发货?
PG1743 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 PG1743 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 PG1743 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 PG1743 安排当日快递或专车加急配送。
Manometer display, pressure switch and transmitter in one unit Excellent readability also over a long distance Rotatable display with LED indication for flexible visualisation Hygienic, robust stainless steel housing for the requirements of the food and beverage industry Flush process connection for use in CIP and SIP processes Integrated temperature measurement via IO-Link Convenient operation via buttons or parameter setting via IO-Link
技术规格
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range | -1...40 bar; -14.5...580 psi |
| -1...40 bar | -14.5...580 psi |
| Process connection | threaded connection G 1 external thread Aseptoflex Vario |
Application
| Special feature | Gold-plated contacts |
| Measuring element | ceramic-capacitive pressure measuring cell |
| Application | flush mountable for the food and beverage industry |
| Media | viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature[°C] [°C] | -25...150 |
| Min. burst pressure | 400 bar; 5801 psi |
| 400 bar | 5801 psi |
| Pressure rating | 125 bar; 1813 psi |
| 125 bar | 1813 psi |
| Vacuum resistance | -1000 mbar; 14.5 psi |
| -1000 mbar | 14.5 psi |
| Type of pressure | relative pressure; vacuum |
| No dead space | yes |
Electrical data
| Operating voltage[V] [V] | 18...30 DC |
| Current consumption[mA] [mA] | 25...260 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | < 0.5 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; IO-Link |
| Electrical design | PNP/NPN |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 125 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20, invertible; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | -25...150 °C; -13...302 °F |
| -1...40 bar | -14.5...580 psi |
| Set point SP | -1...40 bar; -14.5...580 psi |
| Analogue start point | -1...32 bar; -14.5...464 psi |
| -1...32 bar | -14.5...464 psi |
| Analogue end point | 7...40 bar; 102...580 psi |
| 7...40 bar | 102...580 psi |
| In steps of | 0.01 bar; 1 psi |
| 0.01 bar | 1 psi |
| Factory setting | SP1 = 145 psi; SP2 = 133 psi; ASP = 0.00 psi; AEP = 580 psi; dAP = 0.06 s; dAA = 0.06 s |
| -25...150 °C | -13...302 °F |
| Resolution of display[K] [K] | 1 |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,2; (DIN EN IEC 62828-1; Turn down 1:1) |
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,2; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1) |
| Linearity deviation[% of the span] [% of the span] | < ± 0,15; (Turn down 1:1) |
| Zero-point stabilisation[% of the span] [% of the span] | IO-Link, analogue output; 0,1; (see operating instructions zero-point behaviour); display, switching output; 0,2 |
| IO-Link, analogue output | 0,1; (see operating instructions zero-point behaviour) |
| display, switching output | 0,2 |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,15; (Turn down 1:1) |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (Turn down 1:1; per year) |
| Total deviation over temperature range | -25...15 °C; Characteristics deviation ± 0,05 % of the span / 10 K; 15...80 °C; Characteristics deviation; 80...150 °C; Characteristics deviation ± 0,1 % of the span / 10 K |
| -25...15 °C | Characteristics deviation ± 0,05 % of the span / 10 K |
| 15...80 °C | Characteristics deviation |
| 80...150 °C | Characteristics deviation ± 0,1 % of the span / 10 K |
| Notes on the accuracy / deviation | for further details see section Diagrams and graphs |
| Accuracy[K] [K] | ± 0.8 + (0.16 x (ambient temperature - medium temperature)) |
| Repeatability[K] [K] | ± 0,2 |
Response times
| Min. response time of switching output (dAP)[ms] [ms] | 3 |
| Damping process value dAP[s] [s] | 0...99.99 |
| Damping for the analogue output dAA[s] [s] | 0...99.99 |
| Step response time analogue output[ms] [ms] | 7 |
| Dynamic response T05 / T09[s] [s] | < 55 / < 270; (DIN EN 60751 water ; > 0,9 m/s) |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM3 (230,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Common - I&D; Identification and Diagnosis; Function; Measurement data, standard resolution |
| Common - I&D | Identification and Diagnosis |
| Function | Measurement data, standard resolution |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 1.3 |
| IO-Link resolution pressure[bar] [bar] | 0.002 |
| IO-Link resolution temperature[K] [K] | 0.1 |
| IO-Link process data (cyclical) | pressure; 32; temperature; 32; device status; 4; binary switching information pressure; 2; binary switching information temperature; 2 |
| pressure | 32 |
| temperature | 32 |
| device status | 4 |
| binary switching information pressure | 2 |
| binary switching information temperature | 2 |
| IO-Link functions (acyclical) | application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter; Temperature peak counter |
| Supported DeviceIDs | default; 1865 |
| default | 1865 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...70 |
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 67; IP 69; (to DIN EN 60529) |
Tests / approvals
| EMC | DIN EN 61326-1 |
| Shock resistance | DIN EN 60068-2-27; 50 g (11 ms) |
| DIN EN 60068-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6; 10 g (10...2000 Hz) |
| DIN EN 60068-2-6 | 10 g (10...2000 Hz) |
| MTTF[years] [years] | 115 |
| Embedded software included | yes |
| UL approval | UL approval no.; J059; File number UL; E174189 |
| UL approval no. | J059 |
| File number UL | E174189 |
Mechanical data
| Weight[g] [g] | 655.4 |
| Housing | manometer housing |
| Dimensions[mm] [mm] | 155 x 100 x 57 |
| Materials | Housing: stainless steel (316L/1.4404); M12 connector: PPSU; Sealing: FKM; pressure compensation element: PTFE; viewing glass: laminated safety glass 4 mm |
| Materials (wetted parts) | measuring cell: ceramics (99.9 % Al2O3); Process connection: stainless steel (316L/1.4435) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; Sealing: PTFE |
| Min. pressure cycles | 100 million |
| Tightening torque[Nm] [Nm] | 35 |
| Process connection | threaded connection G 1 external thread Aseptoflex Vario |
Displays / operating elements
| 3 | optical operating keys |
| Display | display rotation: 320° |
| Pointer | LED, white ; 72 steps |
| LED bar graph | multi-colour ; 72 steps |
| measured values | alphanumeric display, white 4-digit |
| switching status | LED, yellow |
| device status | LED, red/green |
| Display unit | bar; psi; °C; °F |
| Operating elements | 3; optical operating keys |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |
12个月保修适用于所有全新库存
3个月保修适用于二手及翻新零部件
30天退货未使用零部件退货免收上架费
全球发货全球快速可追踪配送