产品概览
| 库存情况 | 需按需确认 |
| 分类 | All inductive sensors |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
IQ2008 何时可以发货?
IQ2008 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 IQ2008 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 IQ2008 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 IQ2008 安排当日快递或专车加急配送。
Setting options PNP/NPN or NO/NC help to reduce storage costs Long life and robustness thanks to flush installation and a high temperature range Particularly compact housing for use where space is restricted Continuous position feedback via IO-Link Switch points can be easily adapted via IO-Link at any time
技术规格
Product characteristics
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (parameterisable) |
| Communication interface | IO-Link |
| Housing | rectangular |
| Dimensions[mm] [mm] | 20 x 8 x 32 |
Application
| Special feature | Drag chain suitability |
Electrical data
| Operating voltage[V] [V] | 10...30 DC |
| Current consumption[mA] [mA] | < 30 |
| Protection class | III |
| Reverse polarity protection | yes |
Outputs
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 300 |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Switch point IO-Link[mm] [mm] | 1.4...7; (parameterisable) |
| Measuring range IO-Link[mm] [mm] | 0.75...7.5 |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 |
| Hysteresis[% of Sr] [% of Sr] | 3...15 |
| Note on hysteresis | parameterisable |
| Linearity error IO-Link[%] [%] | ± 2; (of the final value of the measuring range) |
| Repeatability IO-Link[%] [%] | ± 1; (of the final value of the measuring range) |
| Temperature coefficient[%/K vom MEW] [%/K vom MEW] | ± 0,6; (-25...70 °C: ± 0,3) |
| Temperature drift | ± 10 %; (of the final value of the measuring range) |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Multiple switching signal; Function; Teach channel; Common - I&D; Identification and Diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Teach channel |
| Common - I&D | Identification and Diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 3.2 |
| IO-Link process data (cyclical) | process value; 16; device status; 4; binary switching information; 2 |
| process value | 16 |
| device status | 4 |
| binary switching information | 2 |
| IO-Link functions (acyclical) | application specific tag; operating hours counter |
| Supported DeviceIDs | default; 1106 |
| default | 1106 |
| Note | For further information please see the IODD PDF file under "Downloads" |
Operating conditions
| Ambient temperature[°C] [°C] | -40...85 |
| Protection | IP 65; IP 66; IP 67; IP 68 |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V; EN 55011; class B |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| EN 55011 | class B |
| Vibration resistance | EN 60068-2-6 Fc; 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| EN 60068-2-6 Fc | 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| Shock resistance | EN 60068-2-27 Ea; 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| Continuous shock resistance | EN 60068-2-27; 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| Fast temperature change | EN 60068-2-14 Na; TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 10 s 50 cycles |
| EN 60068-2-14 Na | TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 10 s 50 cycles |
| MTTF[years] [years] | 787 |
| Embedded software included | yes |
| UL approval | Ta; -25...70 °C; Enclosure type; Type 1; power supply; Limited Voltage/Current; UL approval no.; A015; File number UL; E174191 |
| Ta | -25...70 °C |
| Enclosure type | Type 1 |
| power supply | Limited Voltage/Current |
| UL approval no. | A015 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 79.2 |
| Housing | rectangular |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | 20 x 8 x 32 |
| Materials | housing: diecast zinc special coating; sensing face: PBT orange; LED window: TPU; potting: PUR |
| Drag chain suitability | bending radius for flexible use; min. 10 x cable diameter; bending cycles; > 5 Mio. |
| bending radius for flexible use | min. 10 x cable diameter |
| bending cycles | > 5 Mio. |
Displays / operating elements
| Display | Display operation; 1 x LED, green; switching status; 1 x LED, yellow |
| Display operation | 1 x LED, green |
| switching status | 1 x LED, yellow |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Cable | 2 m, PUR, Ø 4.9 mm; 3 x 0.34 mm² |
12个月保修适用于所有全新库存
3个月保修适用于二手及翻新零部件
30天退货未使用零部件退货免收上架费
全球发货全球快速可追踪配送