产品概览
| 库存情况 | 需按需确认 |
| 分类 | All inductive sensors |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
IIM203 何时可以发货?
IIM203 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 IIM203 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 IIM203 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 IIM203 安排当日快递或专车加急配送。
E1 type approval by the Kraftfahrt-Bundesamt (German Federal Motor Transport Authority) Wide operating temperature range High ingress protection for the requirements of harsh environmental conditions High EMC resistance according to automotive standards Large operating voltage range
技术规格
Product characteristics
| Electrical design | PNP/NPN |
| Output function | normally open |
| Sensing range[mm] [mm] | 22 |
| Housing | threaded type |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 81 |
Application
| Special feature | Increased sensing range |
| Application | Use in mobile and harsh applications |
Electrical data
| Operating voltage[V] [V] | 10...36 DC |
| Current consumption[mA] [mA] | < 10; (only in 3-wire operation) |
| Protection class | II |
| Reverse polarity protection | yes |
Outputs
| Electrical design | PNP/NPN |
| Output function | normally open |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Minimum load current[mA] [mA] | 2; (only in 2-wire operation) |
| Max. leakage current[mA] [mA] | 0.5; (only in 2-wire operation) |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 100 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Detection zone
| Sensing range[mm] [mm] | 22 |
| Real sensing range Sr[mm] [mm] | 22 ± 10 % |
| Operating distance[mm] [mm] | 0...17.82 |
| Increased sensing range | yes |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.45 / copper: 0.4 |
| Hysteresis[% of Sr] [% of Sr] | 1...20 |
| Switch point drift[% of Sr] [% of Sr] | -10...10 |
Operating conditions
| Ambient temperature[°C] [°C] | -40...85 |
| Protection | IP 67; IP 69K |
Tests / approvals
| EMC | automotive area; noise emission and noise immunity: ECE R10; E1 type approval; noise immunity according to DIN ISO 11452-2; 100 V/m; conducted interference in 24 V networks to ISO 7637-2: 2004 (pulse 1 to 4) and ISO16750-2: 2012 (load dump); pulse; 1 2a 2b 3a 3b 4 Load dump; severity level; III III III III III III Test A; failure criterion; C A C A A C C; EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; 0,5 kV mains line to line; EN 61000-4-6 HF conducted; 10 V; EN 55011; class B |
| noise emission and noise immunity: ECE R10 | E1 type approval |
| noise immunity according to DIN ISO 11452-2 | 100 V/m |
| pulse | 1 2a 2b 3a 3b 4 Load dump |
| severity level | III III III III III III Test A |
| failure criterion | C A C A A C C |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 0,5 kV mains line to line |
| EN 61000-4-6 HF conducted | 10 V |
| EN 55011 | class B |
| Vibration resistance | EN 60068-2-6 Fc; 20 g (10...3000 Hz) / -20...50 °C; 50 sweep cycles, 1 octave per minute, in 3 axes |
| EN 60068-2-6 Fc | 20 g (10...3000 Hz) / -20...50 °C |
| Shock resistance | EN 60068-2-27 Ea; 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
| EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
| Continuous shock resistance | EN 60068-2-27; 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| EN 60068-2-27 | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| Fast temperature change | EN 60068-2-14 Na; TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| EN 60068-2-14 Na | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| Salt spray test | EN 60068-2-52 Kb; severity level 5 (4 test cycles) |
| EN 60068-2-52 Kb | severity level 5 (4 test cycles) |
| MTTF[years] [years] | 1089 |
| UL approval | Ta; 0...40 °C; Enclosure type; Type 1; power supply; Limited Voltage/Current; File number UL; E174191 |
| Ta | 0...40 °C |
| Enclosure type | Type 1 |
| power supply | Limited Voltage/Current |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 373 |
| Housing | threaded type |
| Mounting | non-flush mountable |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 81 |
| Thread designation | M30 x 1.5 |
| Materials | threaded sleeve: stainless steel; sensing face: LCP natural; LED window: PEI; lock nuts: brass |
Displays / operating elements
| Display | switching status; 4 x 90° LED, yellow |
| switching status | 4 x 90° LED, yellow |
Accessories
| Items supplied | lock nuts: 2 |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Cable | 6 m, PUR, Ø 5.4 mm; burning behaviour to ECE R118 rev. 2; 3 x 0.5 mm² |
12个月保修适用于所有全新库存
3个月保修适用于二手及翻新零部件
30天退货未使用零部件退货免收上架费
全球发货全球快速可追踪配送