产品概览
| 库存情况 | 需按需确认 |
| 分类 | All inductive sensors |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
IGP200 何时可以发货?
IGP200 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 IGP200 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 IGP200 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 IGP200 安排当日快递或专车加急配送。
For a precise position monitoring on machines Flexible use thanks to large operating temperature range Very high repeatability Reliable transmission of the distance as linearised process value via IO-Link Normally closed / normally open and PNP/NPN adjustable via IO-Link
技术规格
Product characteristics
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (parameterisable) |
| Communication interface | IO-Link |
| Housing | threaded type |
| Dimensions[mm] [mm] | M18 x 1 / L = 60 |
Application
| Special feature | Magnetic-field immune |
| Magnetic-field immune | yes |
| Max. magnetic field immunity[mT] [mT] | 300 |
Electrical data
| Operating voltage[V] [V] | 10...30 DC |
| Current consumption[mA] [mA] | < 20 |
| Protection class | III |
| Reverse polarity protection | yes |
Outputs
| Electrical design | PNP/NPN; (parameterisable) |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 75 |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Switch point IO-Link[mm] [mm] | 1...4.85 |
| Measuring range IO-Link[mm] [mm] | 0.5...5 |
Accuracy / deviations
| Repeatability | < 20 µm |
| Resolution[µm] [µm] | 10 |
| Temperature drift | ± 3 µm/K |
| Linearity deviation | ± 50 µm |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 4.1.1; Measuring and Switching Sensor, 1 channel; Common - I&D; Identification and Diagnosis; Extension; Object detection, switches when value falls below the setpoint; Function; Locator; Function; ProductURI |
| Smart Sensor - SSP 4.1.1 | Measuring and Switching Sensor, 1 channel |
| Common - I&D | Identification and Diagnosis |
| Extension | Object detection, switches when value falls below the setpoint |
| Function | ProductURI |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 3.2 |
| Supported DeviceIDs | default; 1706 |
| default | 1706 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...70 |
| Protection | IP 65; IP 66; IP 67; IP 68; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V; EN 55011; class B |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| EN 55011 | class B |
| Vibration resistance | EN 60068-2-6 Fc; 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| EN 60068-2-6 Fc | 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| Shock resistance | EN 60068-2-27 Ea; 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| Continuous shock resistance | EN 60068-2-27 Eb; 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Eb | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| Fast temperature change | EN 60068-2-14 Na; TA = -25 °C; TB = 70 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| EN 60068-2-14 Na | TA = -25 °C; TB = 70 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| MTTF[years] [years] | 1341 |
| Embedded software included | yes |
| UL approval | Ta; -25...70 °C; Enclosure type; Type 1; power supply; Limited Voltage/Current; UL approval no.; A005; File number UL; E174191 |
| Ta | -25...70 °C |
| Enclosure type | Type 1 |
| power supply | Limited Voltage/Current |
| UL approval no. | A005 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 73.5 |
| Housing | threaded type |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | M18 x 1 / L = 60 |
| Thread designation | M18 x 1 |
| Materials | housing: stainless steel (316L/1.4404); sensing face: LCP white; LED window: PEI; lock nuts: stainless steel (316L/1.4404) |
| Tightening torque[Nm] [Nm] | 7 |
Displays / operating elements
| Display | switching status; 4 x LED, yellow; SIO mode; output stage supplied with current; LED, yellow lights; IO-Link mode; target in measuring range; LED, yellow lights |
| switching status | 4 x LED, yellow |
| output stage supplied with current | LED, yellow lights |
| target in measuring range | LED, yellow lights |
Accessories
| Items supplied | lock nuts: 2 |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection - plug
| Connector | 1 x M12; coding: A |
12个月保修适用于所有全新库存
3个月保修适用于二手及翻新零部件
30天退货未使用零部件退货免收上架费
全球发货全球快速可追踪配送