8 digital outputs with 2 ARated voltage 12 VDCSource connection1-wire connectionPower feed integrated in the moduleIntegrated output protection This module is equipped with 8 outputs for 1-wire connections. The outputs are designed for a source circuit. The nominal output current is 2 A. The output supply is fed directly to the module. An additional supply module is not needed. There is no connection between the module and the I/O supply potential on the bus module.
技术规格
Specifications
| I/O module | 8 digital outputs 12 VDC for 1-wire connections |
| B&R ID code | 0xA4AD |
| Status indicators | I/O function per channel, operating state, module status |
| Module run/error | Yes, using LED status indicator and software |
| Outputs | Yes, using LED status indicator and software (output error status) |
| Supply voltage monitoring | Yes, using software |
| Bus | 0.22 W |
| Internal I/O | - |
| External I/O | 0.82 W |
| Additional power dissipation caused by actuators (resistive) [W] | +4.48 |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user's manual)FTZÚ 09 ATEX 0083X |
| UL | cULus E115267Industrial control equipment |
| HazLoc | cCSAus 244665Process control equipmentfor hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV | Temperature: B (0 to 55°C)Humidity: B (up to 100%)Vibration: B (4 g)EMC: B (bridge and open deck) |
| CCS | Yes |
| LR | ENV1 |
| KR | Yes |
| ABS | Yes |
| BV | EC33BTemperature: 5 - 55°CVibration: 4 gEMC: Bridge and open deck |
| KC | Yes |
| Variant | Current-sourcing FET |
| Nominal voltage | 12 VDC |
| Switching voltage | 12 VDC (-15% / +20%) |
| Nominal output current | 2 A |
| Total nominal current | 8 A |
| Connection type | 1-wire connections |
| Output circuit | Source |
| Output protection | Thermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current")Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads") Reverse polarity protection of supply voltage |
| Supply | External |
| Fuse | Required line fuse: Max. 10 A, slow-blow |
| Diagnostic status | Output monitoring with 10 ms delay |
| Leakage current when the output is switched off | 5 μA |
| RDS(on) | 140 mΩ |
| Peak short-circuit current | <12 A |
| Switch-on in the event of overload shutdown or short-circuit shutdown | Approx. 10 ms (depends on the module temperature) |
| 0 → 1 | <300 μs |
| 1 → 0 | <300 μs |
| Resistive load | Max. 500 Hz, 600 Hz at max. 250 mA load |
| Inductive load | See section "Switching inductive loads". |
| Braking voltage when switching off inductive loads | Typ. 50 VDC |
| Insulation voltage between channel and bus | 500 Veff |
| Additional functions | Outputs can be connected in parallel to increase the output current. |
| Electrical isolation | Channel isolated from bus and I/O power supply |
| Horizontal | Yes |
| Vertical | Yes |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | See section "Derating". |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Operation | 5 to 95%, non-condensing |
| Note | Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately. |
| Pitch | 12.5+0.2 mm |