Modular mechanical design using plug-in modulesIntegrated line filterIntegrated braking resistorIntegrated electronic restart inhibit ACOPOS servo drive, 3x 400-480 V, 1.6 A, 0.7 kW, integrated line filter, braking resistor and electronic safe restart interlock
技术规格
Specifications
| B&R ID code | 0x18D5 |
| Slots for plug-in modules | 3 |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | Evaluation ongoing |
| Functional safety | Yes |
| UL | cULus E225616Power conversion equipment |
| KC | Yes |
| Permissible network configurations | TT, TN |
| Mains input voltage | 3x 400 VAC to 480 VAC ±10% 3x 230 VAC ±10% |
| Frequency | 50 / 60 Hz ±4% |
| Installed load | Max. 2.1 kVA |
| Inrush current | 2 A (at 400 VAC) |
| Switch-on interval | >10 s |
| Integrated line filter per EN 61800-3, category C3 | Yes |
| Power dissipation at device nominal power without braking resistor | 110 W |
| DC bus capacitance | 165 µF |
| Input voltage | 24 VDC +25% / -20% |
| Input capacitance | 5600 µF |
| Current consumption | Max. 1.47 A + Current for motor holding brake |
| Quantity | 2 |
| Continuous current | 1.6 Aeff |
| Switching frequency 5 kHz | No reduction |
| Switching frequency 10 kHz | No reduction |
| Switching frequency 20 kHz | 0.13 Aeff per °C (starting at 40°C) |
| Starting at 500 m above sea level | 0.16 Aeff per 1000 m |
| Peak current | 5 Aeff |
| Nominal switching frequency | 10 kHz |
| Possible switching frequencies | 5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 | Limit value curve A |
| Max. motor line length | 15 m |
| Overload protection | Yes |
| Short-circuit and ground fault protection | Yes |
| Max. output frequency | 598 Hz |
| With wire end sleeve | 0.25 to 4 mm² |
| UL/C-UL-US | 30 to 10 AWG |
| CSA | 28 to 10 AWG |
| Response threshold for open-circuit monitoring | Approx. 245 mA |
| Max. output current | 1.3 A |
| Max. number of switching cycles | Unlimited since implemented electronically |
| Peak power output | 2 kW |
| Continuous power | 130 W |
| Circuit | Sink |
| Input - ACOPOS | Yes |
| Input - Input | No |
| Nominal | 5 to 40°C |
| Maximum | 55°C |
| Low | <5 V |
| High | >15 V |
| Input current at nominal voltage | Approx. 10 mA |
| Switching delay | Max. 2.0 ms |
| Modulation compared to ground potential | Max. ±38 V |
| Enable 0 → 1, ready for PWM | Max. 100 µs |
| Enable 1 → 0, PWM off | Max. 2.0 ms |
| OSSD signal connections | Not permitted |
| Rising edge | 52 µs ±0.5 µs (digitally filtered) |
| Falling edge | 53 µs ±0.5 µs (digitally filtered) |
| Discharge capacitance | 550 nF |
| Power dissipation relative to continuous apparent power | IE2 (10,25) 4.6%IE2 (50,25) 4.6%IE2 (10,50) 4.6%IE2 (50,50) 4.6%IE2 (90,50) 4.7%IE2 (10,100) 4.8%IE2 (50,100) 5%IE2 (90,100) 5.2% |
| Nominal losses in standby mode | 12.5 W |
| Hanging vertically | Yes |
| Horizontal, face up | Yes |
| Standing horizontally | No |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | II |
| Degree of protection per EN 60529 | IP20 |
| Storage | 5 to 95% |
| Transport | Max. 95% at 40°C |
| Operation | 5 to 85% |
| Width | 58.5 mm |
| Height | 257 mm |
| Depth | 220 mm |
| Weight | 2.5 kg |