Specification : |
Short description
I/O module
|
2x M12 interface each with 2 safe type A digital inputs and 2 pulse outputs, 24 VDC, 2x standardized 8-pin M12 device interface each with 1 digital input without safety function and 2 safe type A digital inputs and 2 pulse outputs, 24 VDC and 1 digital output without safety function, 24 VDC, 0.6 A and 1 device power supply, 24 VDC, 2 A
|
General information
B&R ID code
|
0xBB7C
|
System requirements
|
|
Automation Studio
|
3.0.81.15 or later
|
Automation Runtime
|
3.00 or later
|
SafeDESIGNER
|
2.70 or later
|
Safety Release
|
1.2 or later
|
mapp Technology Package
|
mapp Safety 5.7.0 or later
|
Status indicators
|
I/O function per channel, operating state, module status
|
Diagnostics
|
|
Module run/error
|
Yes, using LED status indicator and software
|
I/O function
|
Yes, using LED status indicator and software
|
Blackout mode
|
|
Scope
|
Module
|
Function
|
Module functionality
|
Standalone mode
|
No
|
Max. I/O cycle time
|
1 ms
|
Connection type
|
|
X2X Link
|
M12, B-coded
|
Inputs/Outputs
|
M12 8-pin or M12 5-pin, A-coded
|
I/O power supply
|
M8, 4-pin
|
Power consumption
|
|
Bus
|
0.9 W
|
Internal I/O
|
2.1 W
|
Additional power dissipation caused by actuators (resistive) [W]
|
|
Digital outputs
|
0.216
|
Pulse outputs
|
0.192
|
Electrical isolation
|
|
Channel - Bus
|
Yes
|
Channel - Channel
|
No
|
Certifications
|
|
CE
|
Yes
|
UKCA
|
Yes
|
Functional safety
|
cULus FSPC E361559 Energy and industrial systems Certified for functional safety ANSI UL 1998:2013
|
Functional safety
|
IEC 61508:2010, SIL 3 EN 62061:2005/A2:2015, SIL 3 EN ISO 13849-1:2015, Cat. 4 / PL e IEC 61511:2004, SIL 3
|
Functional safety
|
EN 50156-1:2004
|
ATEX
|
Zone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 - Max. 60°C TÜV 05 ATEX 7201X
|
UL
|
cULus E115267 Industrial control equipment
|
HazLoc
|
cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
|
EAC
|
Yes
|
KC
|
Yes
|
Safety characteristics
EN ISO 13849-1:2015
|
|
Category
|
Cat. 3 when using individual input channels, Cat. 4 when using input channel pairs (e.g. SI1 and SI2) or more than 2 input channels
|
PL
|
PL e
|
DC
|
>94%
|
Mission time
|
Max. 20 years
|
IEC 61508:2010, IEC 61511:2004, EN 62061:2013
|
|
SIL CL
|
SIL 3
|
SFF
|
>90%
|
PFH / PFHd
|
|
openSAFETY wired
|
Negligible
|
openSAFETY wireless
|
<1*10-14 * Number of openSAFETY packets per hour
|
Proof test interval (PT)
|
20 years
|
Safe digital inputs
|
|
EN ISO 13849-1:2015
|
|
MTTFD per channel
|
100 years when using individual input channels, 2500 years when using input channel pairs (e.g. SI1 and SI2) or more than 2 input channels
|
IEC 61508:2010, IEC 61511:2004, EN 62061:2013
|
|
PFH / PFHd per channel
|
<1*10-10
|
PFD per channel
|
<2*10-5
|
24 VDC output
Output voltage
|
24 VDC -15% / +20%
|
Output current
|
2 A
|
I/O power supply
Nominal voltage
|
24 VDC
|
Voltage range
|
18 to 30 VDC
|
Integrated protection
|
Reverse polarity protection
|
Digital inputs
Quantity
|
2
|
Nominal voltage
|
24 VDC
|
Input characteristics per EN 61131-2
|
Type 1
|
Input voltage
|
24 VDC -15% / +20%
|
Input current at 24 VDC
|
Min. 2 mA to max. 7.24 mA
|
Input circuit
|
Sink
|
Input filter
|
|
Hardware
|
≤150 μs
|
Input resistance
|
Min. 3.3 kΩ
|
Switching threshold
|
|
Low
|
<5 VDC
|
High
|
>15 VDC
|
Insulation voltage between channel and bus
|
500 Veff
|
Safe digital inputs
Quantity
|
8
|
Variant
|
Type A
|
Nominal voltage
|
24 VDC
|
Input characteristics per EN 61131-2
|
Type 1
|
Input filter
|
|
Hardware
|
≤150 μs
|
Software
|
Configurable between 0 and 500 ms
|
Input circuit
|
Sink
|
Input voltage
|
24 VDC -15% / +20%
|
Input current at 24 VDC
|
Min. 2 mA to max. 8.28 mA
|
Input resistance
|
Min. 2.9 kΩ
|
Error detection time
|
200 ms
|
Insulation voltage between channel and bus
|
500 Veff
|
Switching threshold
|
|
Low
|
<5 VDC
|
High
|
>15 VDC
|
Line length between signal source (pulse output or external signal) and input
|
Max. 60 m with unshielded line Max. 400 m with shielded line
|
Digital outputs
Quantity
|
2
|
Variant
|
FET, positive switching, output level readable
|
Nominal voltage
|
24 VDC
|
Switching voltage
|
I/O power supply minus voltage drop due to RDS(on)
|
Max. switching frequency
|
See section "Inrush current behavior for output channels".
|
Nominal output current
|
0.6 A
|
Total nominal current
|
1.2 A
|
Output protection
|
See section "Inrush current behavior for output channels".
|
Leakage current when the output is switched off
|
<500 μA
|
RDS(on)
|
300 mΩ
|
Peak short-circuit current
|
See section "Inrush current behavior for output channels".
|
Braking voltage when switching off inductive loads
|
50 VDC
|
Insulation voltage between channel and bus
|
500 Veff
|
Max. capacitive load
|
100 nF
|
Peak output current
|
1 A
|
Pulse outputs
Quantity
|
8
|
Variant
|
Push-Pull
|
Nominal output current
|
40 mA
|
Output protection
|
Shutdown of individual channels in the event of overload or short circuit
|
Peak short-circuit current
|
25 A for 15 µs
|
Short-circuit current
|
100 mAeff
|
Leakage current when the output is switched off
|
0.1 mA
|
RDS(on)
|
60 Ω
|
Switching voltage
|
I/O power supply minus voltage drop due to RDS(on)
|
Total nominal current
|
80 mA
|
Operating conditions
Mounting orientation
|
|
Any
|
Yes
|
Installation elevation above sea level
|
0 to 2000 m, no limitation
|
Degree of protection per EN 60529
|
IP67
|
Ambient conditions
Temperature
|
|
Operation
|
-40 to 60°C
|
Storage
|
-40 to 85°C
|
Transport
|
-40 to 85°C
|
Mechanical properties
Dimensions
|
|
Width
|
53 mm
|
Height
|
85 mm
|
Depth
|
42 mm
|
Weight
|
190 g
|
Torque for connections
|
|
M8
|
Max. 0.4 Nm
|
M12
|
Max. 0.6 Nm
|
|