Specification : |
Short description
Interfaces |
1x RS232, 1x Ethernet, 1x POWERLINK (V1/V2), 2x USB, 1x X2X Link |
System module |
Controller |
General information
B&R ID code |
0xC370 |
Cooling |
Fanless |
Status indicators |
CPU function, Ethernet, POWERLINK, CompactFlash, battery |
Diagnostics |
|
Battery |
Yes, using LED status indicator and software |
CPU function |
Yes, using LED status indicator |
CompactFlash |
Yes, using LED status indicator |
Ethernet |
Yes, using LED status indicator |
POWERLINK |
Yes, using LED status indicator |
Temperature |
Yes, using software register |
Support |
|
Controller redundancy |
No |
Storage health data support |
Yes |
ACOPOS support |
Yes |
Visual Components support |
Yes |
Power consumption without interface module and USB |
8.6 W |
Power consumption for X2X Link power supply |
1.42 W |
Power consumption |
|
Internal I/O |
0.6 W |
Additional power dissipation caused by actuators (resistive) [W] |
- |
Certifications |
|
CE |
Yes |
UKCA |
Yes |
ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X |
UL |
cULus E115267
Industrial control equipment |
HazLoc |
cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5 |
DNV |
Temperature: B (0 - 55°C)
Humidity: B (up to 100%)
Vibration: B (4 g)
EMC: B (bridge and open deck) |
LR |
ENV1 |
KR |
Yes |
ABS |
Yes |
BV |
EC33B
Temperature: 5 - 55°C
Vibration: 4 g
EMC: Bridge and open deck |
EAC |
Yes |
KC |
Yes |
CPU and X2X Link power supply
Input voltage |
24 VDC -15% / +20% |
Input current |
Max. 1.5 A |
Fuse |
Integrated, cannot be replaced |
Reverse polarity protection |
Yes |
X2X Link power supply output
Nominal output power |
7 W |
Parallel connection |
Yes |
Redundant operation |
Yes |
Input I/O power supply
Input voltage |
24 VDC -15% / +20% |
Fuse |
Required line fuse: Max. 10 A, slow-blow |
Output I/O power supply
Nominal output voltage |
24 VDC |
Permissible contact load |
10 A |
Power supply - General information
Status indicators |
Overload, operating status, module status, RS232 data transfer |
Diagnostics |
|
RS232 data transfer |
Yes, using LED status indicator |
Module run/error |
Yes, using LED status indicator and software |
Overload |
Yes, using LED status indicator and software |
Electrical isolation |
|
I/O supply - I/O power supply |
No |
CPU/X2X Link supply - CPU/X2X Link power supply |
Yes |
Controller
CompactFlash slot |
1 |
Real-time clock |
Nonvolatile, resolution 1 s, -10 to 10 ppm accuracy at 25°C |
FPU |
Yes |
Processor |
|
Type |
Atom E620T |
Clock frequency |
0.6 GHz |
L1 cache |
|
Data code |
24 kB |
Program code |
32 kB |
L2 cache |
512 kB |
Integrated I/O processor |
Processes I/O data points in the background |
Modular interface slots |
1 |
Remanent variables |
Max. 256 kB |
Shortest task class cycle time |
400 µs |
Typical instruction cycle time |
0.0075 µs |
Data buffering |
|
Battery monitoring |
Yes |
Lithium battery |
Min. 2 years at 23°C ambient temperature |
Standard memory |
|
RAM |
256 MB DDR2 SDRAM |
User RAM |
1 MB SRAM |
Interfaces
Interface IF1 |
|
Signal |
RS232 |
Variant |
Connection via 12-pin terminal block X20TB12 |
Max. distance |
900 m |
Transfer rate |
Max. 115.2 kbit/s |
Interface IF2 |
|
Signal |
Ethernet |
Variant |
1x RJ45 shielded |
Line length |
Max. 100 m between 2 stations (segment length) |
Transfer rate |
10/100/1000 Mbit/s |
Transfer |
|
Physical layer |
10BASE-T/100BASE-TX/1000BASE-T |
Half-duplex |
Yes |
Full-duplex |
Yes |
Autonegotiation |
Yes |
Auto-MDI/MDIX |
Yes |
Interface IF3 |
|
Fieldbus |
POWERLINK (V1/V2) managing or controlled node |
Type |
Type 4 |
Variant |
1x RJ45 shielded |
Line length |
Max. 100 m between 2 stations (segment length) |
Transfer rate |
100 Mbit/s |
Transfer |
|
Physical layer |
100BASE-TX |
Half-duplex |
Yes |
Full-duplex |
POWERLINK mode: No / Ethernet mode: Yes |
Autonegotiation |
Yes |
Auto-MDI/MDIX |
Yes |
Interface IF4 |
|
Type |
USB 1.1/2.0 |
Variant |
Type A |
Max. output current |
0.5 A |
Interface IF5 |
|
Type |
USB 1.1/2.0 |
Variant |
Type A |
Max. output current |
0.5 A |
Interface IF6 |
|
Fieldbus |
X2X Link master |
Electrical properties
Electrical isolation |
Ethernet (IF2), POWERLINK (IF3) and X2X (IF6) isolated from each other, from other interfaces and from PLC |
Operating conditions
Mounting orientation |
|
Horizontal |
Yes |
Vertical |
Yes |
Installation elevation above sea level |
|
0 to 2000 m |
No limitation |
>2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
Degree of protection per EN 60529 |
IP20 |
Ambient conditions
Temperature |
|
Operation |
|
Horizontal mounting orientation |
-25 to 60°C |
Vertical mounting orientation |
-25 to 50°C |
Derating |
See section "Derating". |
Storage |
-40 to 85°C |
Transport |
-40 to 85°C |
Relative humidity |
|
Operation |
5 to 95%, non-condensing |
Storage |
5 to 95%, non-condensing |
Transport |
5 to 95%, non-condensing |
Mechanical properties
Note |
Order application memory (CompactFlash) separately
Backup battery included in delivery
X20 end cover plate (right) included in delivery
12-pin X20 terminal block included in delivery
Interface module slot covers included in delivery |
Dimensions |
|
Width |
150 mm |
Height |
99 mm |
Depth |
85 mm |
Weight |
400 g |
|